Quick-Applied Flashing Options for Every Detail
April 9, 2019
Versico offers three different types of VersiGard® EPDM Quick-Applied (QA) Flashings to tackle the variety of details found on any given roof. All three feature the proven weatherability of EPDM and come with 30-mil of QA seam tape to create a watertight seal. The primary difference among the three is the amount of cure in the rubber, and the process used to manufacture them.

QA Uncured EPDM Flashing is used to flash irregularly-shaped objects or details with multiple angle changes. The uncured state of the flashing allows the rubber to be formed and stretched into place without reverting to its original shape, like cured rubber. The flashing formulation is designed to cure on the roof with exposure to heat. Since we need to limit heat exposure in the manufacturing process to keep the product uncured, we require all edges to be lap sealed. This is to keep water from getting between the flashing ply and the tape ply while the material cures on the roof. T-joints, corners, and pockets are all made from uncured flashing; which has a 9-month shelf life.

QA Overlayment Strip – often called “semi-cured” flashing – utilizes the same uncured flashing formulation, but is semi-cured with heat during the manufacturing process. The overlayment strip has the dark black look of uncured flashing, but is 70% cured to add tear resistance for stripping in metal edging or end laps. QA Overlayment Strip is packaged without the diamond pattern film as it is removed during the semi-curing process. This gives you an easy way to tell the difference between a roll of QA Uncured Flashing and QA Semi-Cured Flashing. Due to the semi-cured nature of QA Overlayment Strip, it can seal step-offs at splice intersections of 60-mil rubber without the need for T-joint covers. QA Overlayment Strip is better suited to strip-in seams than QA Uncured EPDM Flashing, as you can eliminate the need for lap sealant and T-joints.

QA Cured Cover Strip is made with the same 60-mil non-reinforced membrane as our standard sheeting, and is then laminated to 30-mil of QA seam tape. This product is primarily used for stripping-in metal or end-laps, and offers the same finished appearance as the field membrane. Due to the fully-cured nature and thickness of the product, T-joints are required at splice intersections.

VersiGard White EPDM Peel & Stick Flashing is available in uncured flashing and cured cover strip options; and is approved for use on both EPDM and TPO roofing systems. VersiGard’s White EPDM Peel & Stick Uncured Flashing has a more aggressive cure package to account for the fact that the white flashing will not gain as much heat naturally on the roof. This translates into a shorter shelf life of 6 months. Keeping your white or black uncured flashings cool during long term storage will help you to maximize its shelf life.

Versico has all your flashing needs covered. For more information about pressure-sensitive flashings, please contact your Regional Technical Manager.

    Ron Goodman
    EPDM Product Manager
    Product Marketing
    ron.goodman@carlisleccm.com
February 20, 2020
Code-Required Minimum R-Values

Over the past 10 years, there has been a shift in minimum required R-values. The 2015 International Energy Conservation Code (IECC) is the driving force behind this movement. More than 20 states have adopted the 2015 IECC, or a portion of its provisions, as their statewide energy code. See the chart below for minimum R-values per climate zone. Since 2009, the roofing industry has seen an R-10 increase in the majority of the states. The total minimum insulation thickness has increased from 3.5" (R-20) to 5.2" (R-30) in parts of over 40 states. The map below can help you identify climate zones within your state. Climate zones 4 through 8 have experienced an R-10 increase. Additional resources are provided below to help you determine the applicable energy code and its associated minimum R-value requirements in a given state or local jurisdiction.    1. Minimum Insulation R-value Requirements: Non-Residential, Above Roof Deck    2. The Building Codes Assistance Project For more information on R-value requirements, please contact Brandon Reynolds at brandon.reynolds@carlisleccm.com

Read This Post
February 6, 2020
Polyiso Storage, Handling, and Application Guidelines

It is well known that moisture is detrimental to roof system performance. Wet insulation can lead to several issues including mold, reduced membrane adhesion, and ultimately roof system failure during wind events. Because wet polyiso must be removed and replaced, watertight tie-ins are essential every night. But let's take a step backwards and look at overall polyiso storage before and during installation. An appropriate understanding of storage, handling, and application will result in a properly constructed roof system. Material delivery should be carefully coordinated with the roof installation schedule to minimize outdoor storage. However, short-term outdoor storage can be necessary at times. When storing polyiso outdoors, bundles should not be stored directly on the ground. If possible, they should be stored over a finished surface rather than dirt or grass. Bundles should be covered with a waterproof cover and secured to prevent wind displacement. Exercise care when handling polyiso to prevent breaking or crushing the edges and surfaces. Polyiso should always be installed on dry roof decks and in dry conditions. Apply only as much polyiso as can be covered by completed roofing the same day. Roof surface protection (plywood) should be used in areas where storage and staging are planned to reduce direct, excessive traffic. Tips: Place bundles on pallets or included feet over a finished surface such as gravel, pavement, or concrete. Remove polyiso bundles from trucks with proper equipment. Do not push bundles off the edge of a truck or "roll" a pallet across the roof deck. Follow Versico's requirements regarding product application to ensure adequate performance of the roofing system. For more information, please contact your sales representative.

Read This Post
January 23, 2020
CAV-GRIP 3V in Cold Weather: Best Practices

As mother nature's cold hands grip much of the continent, many roofing contractors are forced close up shop until winter surrenders to spring. For many contractors, the onset of cold weather means delayed progress, but that mentality is changing. Versico's focus on innovation has resulted in new products that make cold weather installations more manageable. One product leading the pack is CAV-GRIP® 3V Low-VOC Adhesive, which can be installed in temperatures as low as 25°F (-4°C)! Like other adhesives, there are guidelines to follow when using CAV-GRIP 3V in cold weather. Here is some advice to live by: STORAGE: Whether at a distributor's shop or on the jobsite, CAV-GRIP 3V should ALWAYS be stored in protected, heated spaces with the temperature maintained above 70°F (21°C). Adhesive can thicken or gel when exposed to colder temperatures for an extended period. When reheating with a heated blanket or hot box, it can take hours to thoroughly heat the contents and re-liquify. It is recommended to reheat for 12-24 hours prior to use. If the spray gun is spitting, sputtering, or clogging, it is a good indication you've got cold material. GUARD AGAINST HEAT SINKS: A "heat sink" is a material or surface that absorbs heat from surrounding objects. Place cylinders on insulation to avoid direct contact with a cold steel or concrete decks. These surfaces will act as a heat sink, rapidly cooling the cylinders. HOT BOXES AND HEAT BLANKETS: Shop-fabricated or manufactured hot boxes and heated blankets are required to keep CAV-GRIP 3V above 70°F (21°C) when working in colder temperatures. Do not use band heaters due to risks associated with overheating a pressurized cylinder. Devising a way to insulate and heat the hoses also aids in keeping the adhesive warm and spraying properly. Removing cylinders from the cardboard box will aid in heat transfer. ROTATION: It's a good idea to preheat cylinders to 90°F (32°C) as a safety factor against wind chill. Rotate cold tanks into a hot box and replace with heated cylinders. SHAKE CYLINDERS TO AGITATE CONTENTS: Shaking cylinders is a good way to avoid settling of contents and to maintain spray pressure. SPRAYING ISSUES OR GUN CLOGGING: If the spray tip begins to spit, sputter, or clog entirely, there are two main culprits: 1. COLD MATERIAL - Clean the gun and hose from the problem cylinder with Low-VOC UN-TACK prior to attaching to a new, warm cylinder after it has been shaken. 2. CLOGGED SPRAY TIP - If spraying stops, remove the brass spray tip and spray the adhesive into a garbage bag. If the adhesive flows through the wand in a straight stream with no hesitation, then the tank is still functional (assuming it's warm). Simply clean or replace the brass tip and begin spraying again. For more information, please contact your regional manager.     Ryan Ferguson     EPDM Product Specialist     Product Marketing     ryan.ferguson@carlisleccm.com

Read This Post
X
Email to your Colleagues >
Separate multiple emails with a comma or semicolon.
Copy Me


Please log in to share this item by email.
Add to a Collection >
Please log in to share this item to your collections.
Private
Private Collection (Change)

Loading...
Invite user by email:
User Invited. Invite another
User Invite Failed, try again.
X
Visibility Options
Public Collection
Anyone with a link can view. No sign-in required.
Private Collection
Only people explictly granted permission can access. Sign-in required.
X

You are now working in your copied collection
Okay