Storing Your Materials During Inclement Weather
March 22, 2019
When storing roofing materials prior to install, it is important to remember most roofing materials are not designed to be stored in cold or inclement weather conditions; especially when ambient temperatures dip below 40°F. Membranes, adhesives, equipment, and contractors will perform differently in colder or inclement weather - so planning and considering how the inclement weather will impact material storage, installation time, and quality is critical.

Membrane: Storing roofing membranes at your job site during warm months is straightforward: keep the rolls off the ground (on pallets), and protect them from moisture by using breathable, waterproof tarpaulins. In inclement weather, temperatures grow colder - the dew point and temperature come closer together; increasing the potential for condensation and frost forming on materials; and storms/winds become more frequent. Keep roofing materials warm and dry by storing them inside a conditioned space or in a heated job trailer. Keeping materials warm and dry will reduce the risk of moisture being introduced into the roof system during construction, and minimize the possibility of deficiencies in the completed roof system. In addition, material rolls will become more rigid as they get colder, requiring additional time to kick out and relax the membrane before installing. In wet or windy conditions, make sure the roof membrane rolls are covered with a breathable-waterproof tarp and that the tarpaulins are secured to prevent wind damage and/or displacement such as with a pallet or bands. Please note that flashings must be heated prior to application, regardless of the season. When these products are heated until warm to the touch, they will be much easier to install, particularly when flashing corners and irregular shapes.

Adhesives/Pressure Sensitive Products: When dealing with membrane adhesives, there are generally two main categories to consider: solvent-based and waterborne adhesives. Recently, the use of waterborne adhesives has been growing steadily because of low-odor and VOC code requirements. Both types of adhesives have similar manufacturer recommendations for storage temperature, typically between 60° and 80°F. Adhesives, primers, or pressure-sensitive products can be stored at temperatures below 60°F but must be restored to between 60°-80°F prior to application for best results. When ambient temperatures are expected to fall below 40°F for an extended period, a heated enclosure or hot box is strongly recommended for jobsite storage. This applies to pressure-sensitive products as well.

Insulation: Polyisocyanurate or polystyrene insulation is typically shipped protected by a plastic wrap, plastic bag, or both. This factory packaging is intended for handling the polyisocyanurate in the manufacturing plant and during transit; it should not be relied upon as protection at jobsites or other outdoor storage locations, unless specified otherwise by the manufacturer.

To ensure your insulation is properly protected in inclement weather, follow these steps:
  1. Store bundles flat and upright with the bottom of the bundles elevated (2” or more) above a finished surface - preferably gravel, pavement, or concrete - rather than on dirt or grass.
  2. Slit the bundle packaging vertically down the center of the two short sides to prevent moisture accumulation within the package.
  3. Completely cover the bundle with a waterproof tarp and secure to prevent wind damage and/or displacement, such as a pallet.
If you follow the steps outlined above for your roofing material storage, it will increase the success and longevity of your installation. For more information about storage of materials in inclement weather, please contact John Greko.



    John Greko
    PVC Product Manager
    Product Marketing
    john.greko@carlisleccm.com
February 20, 2020
Code-Required Minimum R-Values

Over the past 10 years, there has been a shift in minimum required R-values. The 2015 International Energy Conservation Code (IECC) is the driving force behind this movement. More than 20 states have adopted the 2015 IECC, or a portion of its provisions, as their statewide energy code. See the chart below for minimum R-values per climate zone. Since 2009, the roofing industry has seen an R-10 increase in the majority of the states. The total minimum insulation thickness has increased from 3.5" (R-20) to 5.2" (R-30) in parts of over 40 states. The map below can help you identify climate zones within your state. Climate zones 4 through 8 have experienced an R-10 increase. Additional resources are provided below to help you determine the applicable energy code and its associated minimum R-value requirements in a given state or local jurisdiction.    1. Minimum Insulation R-value Requirements: Non-Residential, Above Roof Deck    2. The Building Codes Assistance Project For more information on R-value requirements, please contact Brandon Reynolds at brandon.reynolds@carlisleccm.com

Read This Post
February 6, 2020
Polyiso Storage, Handling, and Application Guidelines

It is well known that moisture is detrimental to roof system performance. Wet insulation can lead to several issues including mold, reduced membrane adhesion, and ultimately roof system failure during wind events. Because wet polyiso must be removed and replaced, watertight tie-ins are essential every night. But let's take a step backwards and look at overall polyiso storage before and during installation. An appropriate understanding of storage, handling, and application will result in a properly constructed roof system. Material delivery should be carefully coordinated with the roof installation schedule to minimize outdoor storage. However, short-term outdoor storage can be necessary at times. When storing polyiso outdoors, bundles should not be stored directly on the ground. If possible, they should be stored over a finished surface rather than dirt or grass. Bundles should be covered with a waterproof cover and secured to prevent wind displacement. Exercise care when handling polyiso to prevent breaking or crushing the edges and surfaces. Polyiso should always be installed on dry roof decks and in dry conditions. Apply only as much polyiso as can be covered by completed roofing the same day. Roof surface protection (plywood) should be used in areas where storage and staging are planned to reduce direct, excessive traffic. Tips: Place bundles on pallets or included feet over a finished surface such as gravel, pavement, or concrete. Remove polyiso bundles from trucks with proper equipment. Do not push bundles off the edge of a truck or "roll" a pallet across the roof deck. Follow Versico's requirements regarding product application to ensure adequate performance of the roofing system. For more information, please contact your sales representative.

Read This Post
January 23, 2020
CAV-GRIP 3V in Cold Weather: Best Practices

As mother nature's cold hands grip much of the continent, many roofing contractors are forced close up shop until winter surrenders to spring. For many contractors, the onset of cold weather means delayed progress, but that mentality is changing. Versico's focus on innovation has resulted in new products that make cold weather installations more manageable. One product leading the pack is CAV-GRIP® 3V Low-VOC Adhesive, which can be installed in temperatures as low as 25°F (-4°C)! Like other adhesives, there are guidelines to follow when using CAV-GRIP 3V in cold weather. Here is some advice to live by: STORAGE: Whether at a distributor's shop or on the jobsite, CAV-GRIP 3V should ALWAYS be stored in protected, heated spaces with the temperature maintained above 70°F (21°C). Adhesive can thicken or gel when exposed to colder temperatures for an extended period. When reheating with a heated blanket or hot box, it can take hours to thoroughly heat the contents and re-liquify. It is recommended to reheat for 12-24 hours prior to use. If the spray gun is spitting, sputtering, or clogging, it is a good indication you've got cold material. GUARD AGAINST HEAT SINKS: A "heat sink" is a material or surface that absorbs heat from surrounding objects. Place cylinders on insulation to avoid direct contact with a cold steel or concrete decks. These surfaces will act as a heat sink, rapidly cooling the cylinders. HOT BOXES AND HEAT BLANKETS: Shop-fabricated or manufactured hot boxes and heated blankets are required to keep CAV-GRIP 3V above 70°F (21°C) when working in colder temperatures. Do not use band heaters due to risks associated with overheating a pressurized cylinder. Devising a way to insulate and heat the hoses also aids in keeping the adhesive warm and spraying properly. Removing cylinders from the cardboard box will aid in heat transfer. ROTATION: It's a good idea to preheat cylinders to 90°F (32°C) as a safety factor against wind chill. Rotate cold tanks into a hot box and replace with heated cylinders. SHAKE CYLINDERS TO AGITATE CONTENTS: Shaking cylinders is a good way to avoid settling of contents and to maintain spray pressure. SPRAYING ISSUES OR GUN CLOGGING: If the spray tip begins to spit, sputter, or clog entirely, there are two main culprits: 1. COLD MATERIAL - Clean the gun and hose from the problem cylinder with Low-VOC UN-TACK prior to attaching to a new, warm cylinder after it has been shaken. 2. CLOGGED SPRAY TIP - If spraying stops, remove the brass spray tip and spray the adhesive into a garbage bag. If the adhesive flows through the wand in a straight stream with no hesitation, then the tank is still functional (assuming it's warm). Simply clean or replace the brass tip and begin spraying again. For more information, please contact your regional manager.     Ryan Ferguson     EPDM Product Specialist     Product Marketing     ryan.ferguson@carlisleccm.com

Read This Post
X
Email to your Colleagues >
Separate multiple emails with a comma or semicolon.
Copy Me


Please log in to share this item by email.
Add to a Collection >
Please log in to share this item to your collections.
Private
Private Collection (Change)

Loading...
Invite user by email:
User Invited. Invite another
User Invite Failed, try again.
X
Visibility Options
Public Collection
Anyone with a link can view. No sign-in required.
Private Collection
Only people explictly granted permission can access. Sign-in required.
X

You are now working in your copied collection
Okay