Cold Weather’s Effect on Flexible DASH Dual Tank Adhesives
March 20, 2019
Maintaining the proper storage and installation temperature of Versico Flexible DASH roofing adhesive materials will improve the string time/rise time and will also assist in achieving the proper viscosity of the materials; which in turn will help to increase yield/coverage of your Flexible DASH materials.

Problem:

When working in the states highlighted below, you will need to pay attention to the average daily temperatures in relation to the storage and installation of Versico Flexible DASH adhesives.



Here is a simple explanation of viscosity:

Viscosity is a complicated and sometimes confusing topic, and understanding how to lower viscosity is a challenge during cold winter months. A fluid that is viscous will be thick, sticky, and semifluid in consistency. You can lower viscosity by adding friction and/or increasing temperature. In short, the warmer the material, the thinner the fluid - meaning less friction and increased material flow.



Proper material temperatures can also affect the performance of the adhesive. When material temperatures are below the recommended levels, the adhesive cannot properly mix due to the increase viscosity. It is always important to keep your adhesives stored and applied at the temperatures recommended by the manufacturer.

Versico’s Temperature Storage and Application Recommendations Flexible DASH Bulk and Dual Tank



Do not store at temperatures above 100°F or below 50°F. Kits stored below 70°F must be given time for the internal material temperature to warm up to 70°F prior to use. When storing or using adhesives in temperatures below 40°F, the adhesive internal temperature must be returned to 70°F prior to use. Placing adhesive in a heated area (70-90°F) for 4 hours should allow liquid adhesive to reach 70-90°F. In colder temperatures, it is recommended to utilize heated blankets to ensure the tanks are kept warm while dispensing the product.

Solution:

In the winter months, proper material temperatures become imperative. Regardless of the urethane adhesive (DASH or Flexible DASH), material temperatures at the time of installation should be 70°F or rising. When temperatures fall below 70°F, urethane adhesives can experience mixture ratio issues. The use of heated blankets or hot boxes should be used to keep material temperatures above 70°F.

Heated blankets make it easy to lower the viscosity of Versico’s Flexible DASH Dual Tank adhesives. Heated blankets come in various ready-to-ship products, including dual tank and single tank adhesive offerings, and pallet blankets. If you need help with material storage or viscosity reduction, Versico has you covered. Contact your local Versico representative for more information.

Versico has partnered with two equipment manufactures that provide heated blankets. For more information, contact 4C’s Spray Equipment, Amped Equipment, or Advanced Roofing Innovations (ARI).

Heated Blanket Viscosity-Improving Products:





Flexible FAST Frequently Asked Questions

Q: How long will it take a heated blanket to warm a cold tank?
A: Tanks can take anywhere from 4-8 hours to heat back up to the proper application temperature.

Q: Can I use a heated band to warm tank or cylinder products?
A: No -under no circumstances should you use a heated band product with a pressurized tank (Dual Tanks or CAV-GRIP™ 3V). Heater bands can reach temperatures of 300°F – 400°F, which will overheat the tank and cause it to explode.

Q: Are heated blankets safe to use with Dual Tanks? A: Yes, heated blankets have a regulated temperature of 80°F - 100°F and are designed to work with pressurized tanks.

For more information about Flexible DASH Adhesives, please contact Austin Kulp.



    Austin Kulp
    Fleece Membranes & Coatings Product Manager
    Product Marketing
    austin.kulp@carlisleccm.com
February 20, 2020
Code-Required Minimum R-Values

Over the past 10 years, there has been a shift in minimum required R-values. The 2015 International Energy Conservation Code (IECC) is the driving force behind this movement. More than 20 states have adopted the 2015 IECC, or a portion of its provisions, as their statewide energy code. See the chart below for minimum R-values per climate zone. Since 2009, the roofing industry has seen an R-10 increase in the majority of the states. The total minimum insulation thickness has increased from 3.5" (R-20) to 5.2" (R-30) in parts of over 40 states. The map below can help you identify climate zones within your state. Climate zones 4 through 8 have experienced an R-10 increase. Additional resources are provided below to help you determine the applicable energy code and its associated minimum R-value requirements in a given state or local jurisdiction.    1. Minimum Insulation R-value Requirements: Non-Residential, Above Roof Deck    2. The Building Codes Assistance Project For more information on R-value requirements, please contact Brandon Reynolds at brandon.reynolds@carlisleccm.com

Read This Post
February 6, 2020
Polyiso Storage, Handling, and Application Guidelines

It is well known that moisture is detrimental to roof system performance. Wet insulation can lead to several issues including mold, reduced membrane adhesion, and ultimately roof system failure during wind events. Because wet polyiso must be removed and replaced, watertight tie-ins are essential every night. But let's take a step backwards and look at overall polyiso storage before and during installation. An appropriate understanding of storage, handling, and application will result in a properly constructed roof system. Material delivery should be carefully coordinated with the roof installation schedule to minimize outdoor storage. However, short-term outdoor storage can be necessary at times. When storing polyiso outdoors, bundles should not be stored directly on the ground. If possible, they should be stored over a finished surface rather than dirt or grass. Bundles should be covered with a waterproof cover and secured to prevent wind displacement. Exercise care when handling polyiso to prevent breaking or crushing the edges and surfaces. Polyiso should always be installed on dry roof decks and in dry conditions. Apply only as much polyiso as can be covered by completed roofing the same day. Roof surface protection (plywood) should be used in areas where storage and staging are planned to reduce direct, excessive traffic. Tips: Place bundles on pallets or included feet over a finished surface such as gravel, pavement, or concrete. Remove polyiso bundles from trucks with proper equipment. Do not push bundles off the edge of a truck or "roll" a pallet across the roof deck. Follow Versico's requirements regarding product application to ensure adequate performance of the roofing system. For more information, please contact your sales representative.

Read This Post
January 23, 2020
CAV-GRIP 3V in Cold Weather: Best Practices

As mother nature's cold hands grip much of the continent, many roofing contractors are forced close up shop until winter surrenders to spring. For many contractors, the onset of cold weather means delayed progress, but that mentality is changing. Versico's focus on innovation has resulted in new products that make cold weather installations more manageable. One product leading the pack is CAV-GRIP® 3V Low-VOC Adhesive, which can be installed in temperatures as low as 25°F (-4°C)! Like other adhesives, there are guidelines to follow when using CAV-GRIP 3V in cold weather. Here is some advice to live by: STORAGE: Whether at a distributor's shop or on the jobsite, CAV-GRIP 3V should ALWAYS be stored in protected, heated spaces with the temperature maintained above 70°F (21°C). Adhesive can thicken or gel when exposed to colder temperatures for an extended period. When reheating with a heated blanket or hot box, it can take hours to thoroughly heat the contents and re-liquify. It is recommended to reheat for 12-24 hours prior to use. If the spray gun is spitting, sputtering, or clogging, it is a good indication you've got cold material. GUARD AGAINST HEAT SINKS: A "heat sink" is a material or surface that absorbs heat from surrounding objects. Place cylinders on insulation to avoid direct contact with a cold steel or concrete decks. These surfaces will act as a heat sink, rapidly cooling the cylinders. HOT BOXES AND HEAT BLANKETS: Shop-fabricated or manufactured hot boxes and heated blankets are required to keep CAV-GRIP 3V above 70°F (21°C) when working in colder temperatures. Do not use band heaters due to risks associated with overheating a pressurized cylinder. Devising a way to insulate and heat the hoses also aids in keeping the adhesive warm and spraying properly. Removing cylinders from the cardboard box will aid in heat transfer. ROTATION: It's a good idea to preheat cylinders to 90°F (32°C) as a safety factor against wind chill. Rotate cold tanks into a hot box and replace with heated cylinders. SHAKE CYLINDERS TO AGITATE CONTENTS: Shaking cylinders is a good way to avoid settling of contents and to maintain spray pressure. SPRAYING ISSUES OR GUN CLOGGING: If the spray tip begins to spit, sputter, or clog entirely, there are two main culprits: 1. COLD MATERIAL - Clean the gun and hose from the problem cylinder with Low-VOC UN-TACK prior to attaching to a new, warm cylinder after it has been shaken. 2. CLOGGED SPRAY TIP - If spraying stops, remove the brass spray tip and spray the adhesive into a garbage bag. If the adhesive flows through the wand in a straight stream with no hesitation, then the tank is still functional (assuming it's warm). Simply clean or replace the brass tip and begin spraying again. For more information, please contact your regional manager.     Ryan Ferguson     EPDM Product Specialist     Product Marketing     ryan.ferguson@carlisleccm.com

Read This Post
X
Email to your Colleagues >
Separate multiple emails with a comma or semicolon.
Copy Me


Please log in to share this item by email.
Add to a Collection >
Please log in to share this item to your collections.
Private
Private Collection (Change)

Loading...
Invite user by email:
User Invited. Invite another
User Invite Failed, try again.
X
Visibility Options
Public Collection
Anyone with a link can view. No sign-in required.
Private Collection
Only people explictly granted permission can access. Sign-in required.
X

You are now working in your copied collection
Okay